Computational Fluid Dynamics Analysis of Elevated Circular Water Tank
Keywords:
Elevated Water Tank, CFD Analysis, Dynamic Analysis, Ansys Modeling.Abstract
Water storage tanks play a vital role in the society for the supply of water. Seismic study of elevated water tank
under partially filled condition is a complex problem. The main purpose of the study is to perceive the seismic
behavior of elevated reinforced concrete water tank in earthquake prone areas. For analysis, elevated circular
water tank has been chosen because, due to high elevation and concentration of huge mass, elevated water tanks
are more susceptible to horizontal accelerations and become more critical requiring a rigorous study. Various
hydrodynamic pressures on the wall and base slab of water tank have been computed by using commercial
Computational Fluid Dynamics (CFD) package. For partially filled condition, different water heights have been
taken in to consideration for the analysis to study the effect of sloshing on the roof and walls of the water tank.
Multiphase and Volume of Fluid (VOF) method were used to analyze the partially filled tank. Comparison has
been made between different tank condition i.e. partially filled condition, full tank condition and empty tank
condition under seismic forces in the workbench platform of ANSYS 18.
Downloads
References
Algreane, G. A., Osman, S. A., Karim, O. A., & Kasa, A. (2009). Dynamic behaviour of elevated concrete water
tank with alternate impulsive mass configurations. In WSEAS International Conference. Proceedings.
Mathematics and Computers in Science and Engineering (No. 2). WSEAS.
Biswal, K. C., Bhattacharyya, S. K., & Sinha, P. K. (2003). Dynamic characteristics of liquid filled rectangular
tank with baffles. Journal of the Institution of Engineers. India. Civil Engineering Division, 84(AOU), 145-148.
Housner, G. W. (1963). The dynamic behavior of water tanks. Bulletin of the seismological society of
America, 53(2), 381-387.
Jain, S. K., & Jaiswal, O. R. (2007). IITK-GSDMA guidelines for seismic design of liquid storage
tanks. National Information Centre of Earthquake Engineering, Kanpur.
Nayak, C. B., & Thakare, S. B. (2017). Investigation of corrosion status in elevated water tank by using
nondestructive techniques in Baramati region. In International Conference on Construction Real Estate,
Infrastructure and Project Management, NICMAR, Pune (pp. 1-17).
Ormeno, M., Larkin, T., & Chouw, N. (2015). Evaluation of seismic ground motion scaling procedures for
linear time-history analysis of liquid storage tanks. Engineering Structures, 102, 266-277.
Patel, C. N., Vaghela, S. N., & Patel, H. S. (2012). Sloshing response of elevated water tank over alternate
column proportionality. International Journal of Advanced Engineering Technology, IJAERS, 3, 60-63.
Shrimali, M. K., & Jangid, R. S. (2002). Seismic response of liquid storage tanks isolated by sliding
bearings. Engineering Structures, 24(7), 909-921